Related Category (13)
Manufacturing Area
Category: Circuit Breakers
Manufacture Stardand: IEC60947-2 Fixing Type Thermal Trip Fixing Type Magnetic trip Rated Current (A) 16,20,25,32,40,50,63,80,100,125,160,200,225
Busway systems in the low-voltage range guarantee the reliable transmission and distribution of power from the transformer through the main distribution board to the load. TBG offers a complete range ...
Category: Electric Insulation Materials
DZ47-63 mini circuit breaker plastic products: Single-pole, twain-pole, triple-pole, four-pole. Characteristic: Beautiful interior, excellent performanceMaterial: Out-body uses the plastic which p...
Nominal frequency 12.000~110.000MHz Frequency tolerance(at 25?)
Category: High Voltage Circuit Breaker & Switch
The VMD5 series indoor circuit-breaker is our independent developed new generation 40.5 kv vacuuum circuit breaker. Its main characters as follows: the conductance circuit is installed in an three-pha...
LKF7 series surge protective leakage circuit breakers are applied in electric circuits or devices for protecting overload, leakage and short circuit. They are especially applied to protect household l...
JVL5-40 RCBO Provides protection against earth fault/leakage current,short circuit,over load,and function of isolation Provides complementary protection against direct contact by human body Effect...
Category: Switches, others
The TKWH Series of weather protected isolating switch Weather protected The TKWH Series of weather protected isolating switches is a robust range of switches suitable for virtually any external ap...
Category: Electronic Circuit Breakers
Type Un (V) 1?m 1cn InA l?n mA The largest off-time hours(s) l?n 2l?n 5l?n 0.25A 500A JAF7 2P 230 500A (ln? 63A 10ln ) (ln> 63A) 6000A 6,10 16,25 32,40 50,63 80 30 15 50 25 75 40...
Application scope: switch protection of household appliance and electrical motor
Category: High Voltage Vacuum Circuit Breaker
VSM series of indoor high voltage vacuum circuit breaker is adopted front and rare construction for their permanent magnetic and vacuum interrupters. The main conducting circuit is with floor-standing...
LED Dot-matrix Display System(with keystroke)Developing and Designing Displaying English,number,short form, complex font and symbol,etc. Display models like moving left,stationary and shining sele...
XHV(GV) series motor protection circuit breaker are mainly used for the overload and short circuit protection of motors in AC 50/60Hz, up to 660V, 0. 1-80A power circuit, as a full-voltage starter to ...
Category: Molded Case Circuit Breaker
Application Field: Typical temperature sensitivity characteristics A special feature of the MK1 series is that the switch is a temperature-sensitive switch. In normal operation and loads up to nomi...
We can supply many types of circuit breaker, 63A,100A,125A,160A,250A,400A,630A,800A,1250A,1600A. ICU:25KA-100KA Ue:690V
Used at the prote ction of compound outlet, power transformer and electrical motor.
AST2721B Induction Colorful Clock IC Mode & Specification Time Normal time display Temp. Temp.range: 0?~50?(32F~22F) Date Year range:2000~2099 Countdown Max.:199M 59S Alarm Three alert modes ...
F372 F374 Alternating furrent and direct current pulsating type Characteristic : AC, DC pulsating type Rated Current: 25A, 32A,40A,63A Leakage acting Current: 30mA,100mA,300mA
1.Our products are (from 125A to 3200A) with CE and ISO certificates 2.All spares are made by ourselves 3.Certificate:CE,ISO9001:2000
Category: Industrial Electric Devices
Construction and Feature -Protection against both overload and short circuit - High short-circuit capacity -Easy mounting onto 35mm DIN rail Technical Data -Pole No:1P/1P+N/2P/3P/3P+N/4P -Rated...