Join Us |Sign In | User Guide | Inquiry Cart (1)
Years

Shenzhen Jumper-medical Equipment Co.,Ltd

Fetal Monitor, Patient Monitor, Fetal Doppler, Angelsounds, Multiparameter Fetal Monitor, Manufacturer and Supplier - China(CN)

HomeProductsCompany ProfileNewsInquiryRank (0)

Information for Buyer

  • Shenzhen Jumper-medical Equipment Co.,Ltd
  • OEM Service: No
  • Register Time: 2009-07-28

  • (Shenzhen , China(CN)) Map
  • Local time: 10:17:20 2009-12-27
  • Phone: +86 /755-26696279
  • Contact Person: Roger.Lee

Products Detail

Multi-parameter Patient Monitor (JPD-800A)

Rank :
  • Business Information:
  • Certification : CE FDA ISO : 13485:2003
  • FOB Port : Shenzhen
  • Delivery Time : 7 working days upon payment
  • Made In : China(CN)

Product Feature:

Multiparameter Monitors 10.4กจ Display
JPD-800A
Features:
10.4กจ high Brightness FTF LCD
1-8 Channel Waveform Display
7 Channel ECG Waveform Display;ST Segment analysis;Arrhythmia Analysis
Anti-movement and low perfusion SPO2 Measurement
Pace pulse Detection
Defibrillation and ESU Protection
OxyCRG diagram;Drug Dose Calculation
Blood Dynamics Analysis
Venous Punch
Flexible parameter configuration

Specification:
ECG
ECG Cable:5 Leadwires
Lead Section
Lead I,II,III/AvR,AvL,AvF/Vgain(mm/mV):1/4,1/2,1,2,4
Frequency response:
Diagnosis:0.05-100Hz
Monitor:0.5-40Hz
Surgery:1.0-25Hz
Sweep Speed(mm/Sec):6.25,12.5,25,50
Heart Rate range:0-350 BPM
Heart Rate accuracy:กำ1%
ST Segment Deviation Analysis:-0.8~+0.8mV
ST accuracy: กำ0.02mV

Non-Invasive Blood Pressure
Measurement Type: Adult,Pediatric,Neonatal
Meansurement Range:
Systolic 4.0-270mmHg
Diastolic 20-200mmHg
Mean 30-220mmHg
Accuracy: กำ3mmHg or 2%(choice max)
Resolution:1mmHg
Protection:over pressure


Pulse Oximeter
SPO2 measurement range:0-100%
Accuracy: กำ2% at 70-100%(No specification under 70%)
Resolution:1%
Pulse measurement range:30-250BPM
Accuracy: กำ2% or 1BPM(Choice Max)
Resolution:1 BPM

Respiration Rate:
Measurement Range:0-120 BPM
Accuracy: กำ1 BPM or 5%(choice max)
Resolution:1 BPM

CO2:
Measurement Range:
0%-10.0%(in Co2 and et CO2)
Accuracy: กำ2 mmHg(5% Measurement Value)
Response Time:180ms

IBP:
Channel number:2ch
Range:-40-+330mmHg
Accuracy: กำ4mmHg or กำ4%(choice max)
Resolution:1mmHg

Environment
Operation Storage Temperature:5~40ขJ
Storage Temperature:-20~70ขJ
Relative humidity:?80%
Storage Temperature: ?95%

Temperature:
Channel number:2ch
Measurement range:25-45ขJ
Accuracy: กำ0.1ขJ
Resolution:0.1ขJ
Response time: ?3 Min

Power requirements:
Input:98-260V AC,50/60 Hz
Consumption: ?80VA

Product Specifications:

Multiparameter Monitors 10.4กจ Display
JPD-800A
Features:
10.4กจ high Brightness FTF LCD
1-8 Channel Waveform Display
7 Channel ECG Waveform Display;ST Segment analysis;Arrhythmia Analysis
Anti-movement and low perfusion SPO2 Measurement
Pace pulse Detection
Defibrillation and ESU Protection
OxyCRG diagram;Drug Dose Calculation
Blood Dynamics Analysis
Venous Punch
Flexible parameter configuration

Specification:
ECG
ECG Cable:5 Leadwires
Lead Section
Lead I,II,III/AvR,AvL,AvF/Vgain(mm/mV):1/4,1/2,1,2,4
Frequency response:
Diagnosis:0.05-100Hz
Monitor:0.5-40Hz
Surgery:1.0-25Hz
Sweep Speed(mm/Sec):6.25,12.5,25,50
Heart Rate range:0-350 BPM
Heart Rate accuracy:กำ1%
ST Segment Deviation Analysis:-0.8~+0.8mV
ST accuracy: กำ0.02mV

Non-Invasive Blood Pressure
Measurement Type: Adult,Pediatric,Neonatal
Meansurement Range:
Systolic 4.0-270mmHg
Diastolic 20-200mmHg
Mean 30-220mmHg
Accuracy: กำ3mmHg or 2%(choice max)
Resolution:1mmHg
Protection:over pressure


Pulse Oximeter
SPO2 measurement range:0-100%
Accuracy: กำ2% at 70-100%(No specification under 70%)
Resolution:1%
Pulse measurement range:30-250BPM
Accuracy: กำ2% or 1BPM(Choice Max)
Resolution:1 BPM

Respiration Rate:
Measurement Range:0-120 BPM
Accuracy: กำ1 BPM or 5%(choice max)
Resolution:1 BPM

CO2:
Measurement Range:
0%-10.0%(in Co2 and et CO2)
Accuracy: กำ2 mmHg(5% Measurement Value)
Response Time:180ms

IBP:
Channel number:2ch
Range:-40-+330mmHg
Accuracy: กำ4mmHg or กำ4%(choice max)
Resolution:1mmHg

Environment
Operation Storage Temperature:5~40ขJ
Storage Temperature:-20~70ขJ
Relative humidity:?80%
Storage Temperature: ?95%

Temperature:
Channel number:2ch
Measurement range:25-45ขJ
Accuracy: กำ0.1ขJ
Resolution:0.1ขJ
Response time: ?3 Min

Power requirements:
Input:98-260V AC,50/60 Hz
Consumption: ?80VA

Contact Now
Send Inquiry Click Here

Other Related Products

Shenzhen Jumper-medical Equipment Co.,Ltd GoHomeProduct ShowroomCompany ProfileNewsInquiryRank (0)