HongDu Testing Equipment CO.,LTD.
test, tester, chamber, flame, apparatus, Manufacturer and Supplier - China(CN)
HD-9 Power Plug Integrated Tester (HD-9)
Product explanation:
This tester is a integrated tester for plug.It is used to test the breakover,polarity,insulation,high-volt,leakage current of power plug.It meets the requirements of many national and international standards such as BIS, UL, CSA, VDE, BSI, DIN, CCC, IEC,etc.It is a totally automatic testing machine makes your operation more convenient and simple.
Features:
* All of the test subjects will done automatically.
* The inner/outer high-volt value and persistence period can be adjusted separately.
* Test speed is quick,all test subjects will be achieved only in less than 2 seconds.
* The PLC control system comes from Mitsubishi,Made In Japan.
* The relay comes from Schneider,Made In French.
* If the sample is incompetent,there is a alarm by noise and alarm light.
* If the sample is incompetent,this machine will stop at once and show you which subject is incompetent.After you push the emergency button it will restart to a new test.And a switch with key can be made to order to replace the high-volt starting button,it is very useful,because when a alarm happen,the operaters can not restart this machine,only when the managers have checked over and restart it by the key the machine will be working again.
* When test over,the sample will be pushed out automatically,and a T or other characters will be marked on it(only english characters).
Polarity test Test E,L,N wires in sequence
Insulation test high-volt DC 500V +- 10%
Insulation resistance 2,7,20,50,100M[(can be made to order)
Inner high-volt 0~5KV +-5% (adjustable)
Outer high-volt 0~5KV +-5% (adjustable)
Leakage current 0.5,1,3,5,10mA(can be made to order)
Rated power 500VA
Cylinder power compressed air with 0.4 to 0.6Mpa
Dimensions 675mm W,480mm D,520mm H
Power source AC 220V +-10%,50Hz
Weight 35 kg, approximate