Products Detail

Multi-Parameter Patient Monitor 12.1 Inch (RSD2003)

  • Business Information:
  • Mini Order : 10
  • Packaging : carton
  • FOB Port : shenzhen
  • Made In : China(CN)

Product Feature:

Features:
1. 12.1 inch TFT display;
2. Delicate and compact, high-resolution screen;
3. Friendly and configurable user interface;
4. Suitable for adult, pediatric and neonatal patients;
5. Flexible knob operation;
6. 256 hours trend review
7. 7-channel and 12-channel combined;
8. 3 heart rate sources selectable;
9. Able to apply to multiple clinical cases.

Product Specifications:

Specifications:
ECG
Lead selection: 7 leads
Heart rate measurement :0-300bpm (adult),0-350bpm(pediatric and neonate)
Accuracy:1bpm
ARR analysis
Auto ST detection
ST segment range :-2.0mv to + 2.0mv
Sweep speed :12.5/25/50mm/s
Frequency response :0.05 to 100 HZ
Defibrillation protection
NIBP
Measurement method: oscillometric
Parameters :Systolic ,Diatolic, Mean
Unit : mm Hg or Kpa
Operation mode :auto ,manual
Cuff pressure range: 0-320mm Hg
SPO2
Measurement and alarm range :0-100%
Resolution :1%
Accuracy: 50-69%,2%;70-100%,1%
Pulse rate range:0-255bpm
Pulse rate accuracy:1bpm
Refresh time :1 second
RESP
Measurement mode : thoracic
Impedance respiration rate and alarm rage :0-150brpm
Accuracy:2bpm
TEMP
1 channel (2 channels optional)
Measurement and alarm limit:15-45 degrees
Standard probe: skin surface (rectal/esophageal optional)
Unit : Celsius/Fahrenheit
Accuracy:?.1 degrees
Resolution :0.1 degrees
Environment
Working
Temperature:10-50 degrees
Relative humidity:=70%(non-condensing)
Barometric pressure:86-106kPa
Transport
Temperature:-20 to 55 degrees
Relative humidity:=95%(non-condensing)
Barometric pressure:50-106kPa
Power
100-250VAC,47-63HZ
Power input :25W
Battery
Internal lead acid rechargeable battery
Demensions
Size :168(D)x356(W)x276(H)
N.W 6KG

Accessories
Standard
1 main unit
1 5 lead ECG cable
1 SPO2 cable
1 NIBP cuff
1 Temp probe
1 ground wire
1 manual operation
Optional:
Recorder, 2 IBP,

FacebookTwitterLinkedinAdd to my favorite Print this pageForward this page