E2002-D Keyboard Reader/Controller

(access control 06)
Categories:  ALL / Security and Related Products / Access Control Systems & Products / Access Control
Sign in to add to "My Favorite"   
 
E2002-D Keyboard Reader/Controller manufacturer & Supplier
Enlarge this image

Product Feature
Specification

Supply Voltage: DC12V

Working Current: less than 1000 mA

Static current: less than 80 mA

User capacity: 200 passwords

Operation Temperature: -10¡«C-70¡«C

Operation Humidity: 10%-90%



Wire Connection


Red line: +12V

Black line: GND

Orange line + Block line: Switch

Blue line (+) + Black line (-): Electricity lock

Yellow line: Empty

Black line: GND

Brown line + green line: Doorbell

Product Specifications
  • Access control machine program method
  • 1. Password Opening Door Mode.
  • *Press Key # four times, the Buzzer make long sound BI, POWER (Red), OK (Green), Mode (Yellow) is on at the same time.
  • *Input 5 digits PIN (Default Password is 12345), OK (Green) is off. The machine enters Making Program Status.
  • *Press key 2, MODE light (Yellow) is on, POWER (Red) and OK (Green) light are off.
  • *Input 5 digits password to open a door (Such as: 00008), the POWER (Red) and OK light (Green) flash.
  • *Press Key 6 to Exit programming status.
  • 2. Other Setting
  • a. Change Default Programming Password
  • *Press key 1, The MODE (Yellow) light is on, POWER (Red), OK (Green) light is off.
  • *Input PIN as your will (Example, 23456), the Buzzer make a short sound of BI, OK (Green) is on, POWER (Red), MODE (yellow) is on, PIN has changed successfully. Press Key 6 to Exit. Note: The PIN should be kept; you will need it to enter the Making Program Mode next time. If PIN forgotten, please execute Machine Initial Step.
  • b. delete the single password
  • *Press key 3, MODE light (yellow) is bright, POWER (Red) and OK (green) light are off.
  • *Input 4 character user series No that needs to be deleted. (Series No on card, such as: 0008), a sound BI will be heard. This means the deletion is successful. Press Key 6 to Exit
  • c. Delete all passwords
  • *Press key 4, BI will be heard twice. All the registered passwords are deleted. Press Key 6 to Exit
  • d. Open Door Time Setting
  • *Press key 5, MODE light (Yellow) is bright, POWER (Red) and OK (Green) are off.
  • *Input 2 character as the door open time (Such as: 05, means that the door open time is 5 second), sound BI will be heard twice, this means the door open time setup is successful. Press Key 6 to Exit