Product Feature
1.Size 00 probe for coaxial contact pin replacement.2.18GHz Microwave switches and microwave cables assembly.
3.ESD protection includes ionized fan and discharge before test function to prevent TDR meter from damage.
4.GPIB interface.
5.Windows 2000 menu driven software structure.
6.Daily, monthly histogram reports produced by CPK calculation
Dimension
Specification
Test point 20 points (STD); 100 points ( MAX)
System Bandwidth DC-18GHz
Test Speed 0.45 sec/point
Testable PCB size 660mm x 540mm
Controller P4(or above), 2.0G
15" LCD monitor
40GB HDD
Printer 44 column 2 color strip printer
Weight Main unit : 160kgs
Press down unit : 290kgs
Compressed air 5kg/cm2
Cylinder 125?200mm
Power requirement AC source : 100/110/120V
220V/240V, 50Hz~60Hz
Power consumption : 700VA
Environment Temperature : 22
Humidity : <55%
TDR meter Agilent 86100A-Digitizing Oscilloscope
Agilent 54754A-Differential TDR module
Polar-CITS 800S2
Tektronix-TDS8200-Digital sampling Oscilloscope
80E04-20GHz Dual-channel electrical TDR sampling module
TDR 2000I ATE
Feature
Marginless board testing design. Test points around board margin are testable.
The precise position design is to prevent the board from injury and rebound caused by high speed transportation.
This design is 60%~70% time-saving than traditional systems.
Good repeatability and reproducibility.
Adopting GPIB interface to connect with Tektronix, Agilent and Polar meter.
Adopting 18GHz semirigid cable to fixture.
Auto discharge before test to avoid damaging the meter.
TDR trace parameters, such as offset, trace length and auto learning.
Intranet capability and real time monitor system
Dimension
Specification
Test point 20 points (STD); 100 points ( MAX)
System Bandwidth DC-18GHz
Test Speed 0.45 sec/point
Testable PCB size min.50x100mm, max.360x400mm
Thinkness 0.5~2.0mm
Test inspection time 700pcs/hr
Machine operation time Approx. 3.5sec
Micro-Adjust
Jig Steadying Precision : 0.01mm
Loading section Capacity : 220PCBs (1.6mm)
Pass section Capacity :150 PCBs (1.6mm)
Fail section Capacity :150 PCBs (1.6mm)
Controller P4(or above), 2.0G
15" LCD monitor
40GB HDD
Printer Epson printer
Weight 600kgs
Compressed air 5kg/cm2
Power requirement AC source :
220V/240V, 50Hz~60Hz
Power consumption : 700VA
Environment Temperature : 22
Humidity : <55%
TDR meter * Please refer to TDR 2000
Product Specifications
Test point 20 points (STD); 100 points ( MAX)System Bandwidth DC-18GHz
Test Speed 0.45 sec/point
Testable PCB size 660mm x 540mm
Controller P4(or above), 2.0G
15" LCD monitor
40GB HDD
Printer 44 column 2 color strip printer
Weight Main unit : 160kgs
Press down unit : 290kgs
Compressed air 5kg/cm2
Cylinder 125?200mm
Power requirement AC source : 100/110/120V
220V/240V, 50Hz~60Hz
Power consumption : 700VA
Environment Temperature : 22?
Humidity : <55%
TDR meter Agilent 86100A-Digitizing Oscilloscope
Agilent 54754A-Differential TDR module
Polar-CITS 800S2
Tektronix-TDS8200-Digital sampling Oscilloscope
80E04-20GHz Dual-channel electrical TDR sampling module