Pure sine wave three phase online uninterruptible power supply ups 10~400KVA

Pure sine wave three phase online uninterruptible power supply ups 10~400KVA

Business Information

  • Min. Order : 1
  • Certificate : CE,,,,,,,,,,,,SGS,TUV
  • FOB Port : shenzhen
  • Made In : China(CN)
  • Packaging : wooden packing as standard package
  • Supply Capability : 2000pcs/year
  • Delivery Time : within 30days after full payment
Favorites

Product Features

Powervalue (Ⅱ) is upgraded DSP controlled Online LF UPS with output isolation transformer. It can be your perfect large capacity power shield for your critical and industrial load.

QUALITY POWER SUPPLY
HRD PV(II)series is an On-Line double conversion (VFI) UPS with isolation output transformer, unit capacity from 10KVA to 400KVA. It is immune to the interferences on the electric power supply line as it has special input and output filters. World leading DSP technology, with high speed DSP processor are adopted to guarantee systems high stability and giving stable output power supply for all kinds of harsh load. 

PERFECT APPLICATION

Middle and large data center, Telecom, FinanceTraffic, Defense, Medical, Education, Energy, Manufacture, Industry, etc.

MAXIMUM RELIABILITY 
The advanced DPS technology appliance considerably improves reliability, since a reduction in electronic components lowers the likelihood of breakdowns. Digital control is provided by the microprocessor that, in the PV(II) series controls all the internal parameters, thus increasing reliability and performance. In parallel connections, digital control ensures balance of the currents, which generally change over time due to phenomena such as vibrations and temperature, between the UPS units and the exchange of information with no need for manual tuning. MTBF >200,000h. PV(II) has been designed so that it can be connected in parallel even after the installation of the first unit. The power availability can be increased thanks to various configurations available such as the parallel configuration, the Dual Bus function and the Dynamic Dual Bus system.

HIGH SPEED DSP PROCESSOR

Ensuring the operation more fast and stable 

OUTPUT 100% UNBALANCE LOAD
The ups can accept 3phase 100% unbalance load to satisfy kinds of load configuration.

ECO function

under good power condition, UPS can work in ECO mode, efficiency reach 98%, green and energy saving;

UPS FOR INDUSTRIAL LOADS
PV-Plus with its strong overload capability, output galvanic isolation and low harmonic current distortion, is the ideal solution for industrial applications.

Thanks to the high battery current, PV Plus Series is suitable to work with large battery banks as it can guarantee recharging in 10 hours as recommended by the battery manufacturer.

OPERATING FLEXIBILITY

All power ratings of the PV(II) series can also be used as Frequency Converters 50 to 60 Hz and vice versa.

COLORFUL MULTIFUCTIONAL PANEL
The 7 inch colorful multifunctional panel allows easy and humanized operation of the UPS. It gives access to the most important parameters: status and alarms, control commands, input, output, battery measurements (power, current, voltage, frequency and temperature) and settings. The PV(II) series diagnostics system includes up to 128 alarms or messages allowing precise and detailed identification of any event.

Advanced Battery Management (ABM)
Optimal battery management includes:

· Periodic battery test, and automatically transfer between boost charging and float charging to extend battery lifespan

· Automatically adjusting the battery charging current according to battery capacity

· Recharge temperature compensation (optional)

· Remaining  back up time display

MAXIMUM SAFETY FOR PERSONNEL
The back feed protection device prevents any voltage back feed in the upstream distribution board, thus ensuring the safety of the maintenance personnel.

FULL FRONT ACCESS AND CONVENIENT CABLE CONNECTION
Full frontal access is for all power and electronic components, which reduces the floor space required and consequently reduces the installation costs. Configured with top and bottom cable connection

PERFECT HUMAN-MACHINE COMMUNICATION
UPS Monitor software displays the most important information such as the input and output voltage, the load applied, the remaining back-up time, etc., in the form of bar graphs. The software is able to provide information even in the event of a failure, in support of the fault diagnostics. The UPS Monitor software can be used to program the automatic shutdown of all open systems in the event of a prolonged black out. PV Plus can also operate with a network agent for applications on LAN or WAN networks.

The UPS contains the following hardware interfaces:

· RS232 /RS485 interface

· Dry contacts: battery lowbattery dischargebypass/breakdown

· EPO (Emergency Power Off) contact for UPS shutdown using the remote emergency button. 

· SNMP card(optional)

ADVANCED PARALLEL
Maximum parallel up to 8 units and share the common battery pack.10-80kva parallel with parallel card only ; 100kva-400kva, parallel card  with  weaver reactance and different capacity UPS can be also be parallel;

DYNAMIC DUAL BUS SYSTEM
Two independent systems set in Dual Bus Configuration can be merged together at any time for system expansion or maintenance. This provides a lot of flexibility in your installation in case of maintenance or when it is necessary to change the redundancy level of both systems.

EVENT LOG

1000 historical events can be saved, which is easy for tracing ups operation status and useful for maintenance 

Technical specification:

1)  10-120KVA specification

Model

PV3310ii

PV3315ii

PV3320ii

PV3330ii

PV3340ii

PV3360ii

PV3380ii

PV33100ii

PV33120ii

Capacity

10KVA

15KVA

20KVA

30KVA

40KVA

60KVA

80KVA

100KVA

120KVA

system

Output PF  

0.8(lag)

System efficiency  (inverter mode)

92%(@100% load) ;90% @50%load;

System efficiency  (ECO mode)

98%(@100%load)

Maximum leakage current

100(mA)

MTBF

Above 200,000hours

Dry contact

 Standard: 3 types signal(BAT. low,battery mode,bypass /failure)

Optional:14 dry contact output: 12Vdc 80mA

Communication interface

Standard RS232,optional: RS485 / MODBUS

Operation temperature

0 ~ 40 °C

Humidity

95 % (non-condense)

Cooling

Forced air(speed varying according to load percent)

Max. altitude

Within 1000m(every 100increase,capacity decrease -1%), Maximum 4000m

Noise (dB)

52 ~ 58

IP protection

(EN 60529)

IP20

Input/output way

Bottom /rear

Safety standard

safety:GB4943 ,EN 50091-1;EMI:GB7260.2,GB/T 17626.2~5EMC, EN 50091-2

Physical

W *D*H(mm)

600*600*1280

800*800*1480

800*800*1800

Weight(Kg)

195

210

220

305

340

500

600

800

950

AC input

Rated voltage

 380/400/415VAC Three-phase three-wire

Input voltage range

± 15 %- ± 25 % adjustable)

Rate frequency

50 / 60 Hz  auto-sense

Frequency range

50/60Hz+/-5Hz

Input soft start function

0 - 100%,10-300s(settable)

Input power factor 

Reachable 0.99(plus harmonic filter

Input current harmonic component(THDi )

Can <5%(plus harmonic filter

Max. input current [A]

18

27

36

54

72

108

144

180

216

The output characteristic of the rectifier

Maintain the voltage (20°C)

Battery type1 and 2 :V =435Vdc (2.266 x el.)

Battery type 3 :V =424Vdc (2.21 x el.)

 Battery type 0:the voltage value between type 1and 2,

Voltage regulating range: V =400~460Vdc

Charging voltage (20°C)

Battery type1 and 2 :V (%recharging<95%) = 445Vdc (2.32 x el.)

Battery type 3 :V (%recharging<95%) = 460Vdc (2.4 x el.)

Battery type 0: the voltage value between type 1and 2

Voltage regulating range: V =400~460Vdc

The highest charging voltage

445V

The charger output voltage regulation accuracy

1%

DC ripple voltage component

≤1%

Battery

Unit numberrated voltage

384VDC(360-384v,selectable)

Charging current settings

0.1C(battery capacity)

The battery discharge end voltage

Battery type 1,2 and 3:no-load discharge current,V min=346 [V dc]

Battery type 1,2 and 3:output current =Ah capacity,V min=316 [V dc]

Battery type 1,2 and 3:output current >Ah capacity,V min=306 [V dc]

Battery type 0: the factory set the default values,V min=320 [V dc]   

Regulating range: V min =300~360[V dc]

Inverter output

Rated capacity  [KVA]

10

15

20

30

40

60

80

100

120

Rated power  [KW]

8

12

16

24

32

48

64

80

96

Rated voltage [V]

 380/400/415VAC  three-phase four-wire

Rated current  [A]

12

18

24

36

48

72

96

120

144

Phase voltage setting

200 ~ 244 V (control board)

Peak factor

31

Waveform

Sine wave

Voltage phase shift (degrees)           100% balanced load

± 1'

Voltage phase shift (degrees)

100% unbalanced load

± 2'

Phase voltage difference         100% balance load

± 1 %

Phase voltage difference         100% unbalanced load

± 3 %

Total harmonic content(THD v)                                100% linear load

<2%

Total harmonic content   (THD v)                         100% non-linear load

<5%

Steady-state voltage stability

± 1 %

Transient voltage response

± 5 % within 10ms

Rated frequency

Same as input

Frequency stability

When asynchronous,± 0.5 %;synchronization,± 2 %

can be set to ± 1~5 %,by the panel operation

Overload

  600’ / 10’ / 1’ 110/125/150% rated current

Short circuit 0.1s

Double input

Inverter efficiency           (load 100%)

98%

Bypass

Rated capacity [KVA]

10

15

20

30

40

60

80

100

120

Rated voltage [V]

 380/400/415VAC Three-phase four-wire

Input voltage range

±15 %can be adjusted from the control panel ± 10 %± 20%

Rated frequency [Hz]

50 / 60

Frequency range

±2 %can be adjusted from the control panel ± 5 %

“STAND-BY ON”Eco mode, the bypass switch to invertertransfer time

2~5ms

Inverter/bypass transfer time

<1ms

Overload

10’/1’/18” 150/175/200% Rated current 

Standard configuration

Feed flow protection, bypass independently isolated

 

2)  160-400KVA product specification parameter table

Model

PV33160 ii

PV33200 ii

PV33250 ii

PV33300 ii

PV33350 ii

PV33400 ii

Capacity

160KVA

200KVA

250KVA

300KVA

350KVA

400KVA

6 pulse

12 pulse

6 pulse

12 pulse

6 pulse

12 pulse

6 pulse

12 pulse

6 pulse

12 pulse

6 pulse

12 pulse

System parameter

Output power factor 

 0.8(lag)

Overall efficiency (normal model)                 Load 100%

94%

Load 50%

92%

Overall efficiency

ECO mode)              Load 100%

98%

Maximum leakage current(mA)

100

Standby economic model

Standard functions

Mean time before failure(MTBF)

Above 200,000 hours

Dry contact signal

 Standard three control signal (battery lowbattery dischargebypass/breakdown)

Optional 14 control signaloutput 12Vdc 80mA

Computer monitors port

Standard S232,optional ODBUS

Running temperature

0 ~ 40 °C

Maximum relative humidity

95 % (non-condensing)

Cooling

Forced ventilation (fan speed changing with load)

Maximum altitude

1000m rated power(Rising 100m lower 1%) maximum 4000m

Noise dB

54 ~ 62

Protection class

(EN 60529)

IP20

Inlet and outlet of the wire way

Bottom /rear

Safety standard

 Safety: GB4943,EN 50091-1;electromagnetic compatibility: GB7260.2,

GB/T 17626.2~5EMC,EN 50091-2

Physical parameter

Wide (mm)

1100

1400

1100

1400

1400

1400

1400

1400

1600

1600

1600

1600

Deep*high (mm)

800*1800

1000*2000

1100*2000

Weight(kg)

1200

1550

1350

1750

1500

1950

1650

2150

1850

2400

2100

2700

The input rectifier features

Rated voltage

 380/400/415VAC  Three-phase three wire

Voltage range

± 15 % ± 25 % adjustable)

Rated frequency

50 / 60 Hz automatic identification

Frequency range

45 ~ 65

Input power

slow start function

Yes,0 - 100%,can be set to 10-300 seconds

Input power factors cosφ

Reachable 0.99(plus harmonic filter)

Input current harmonic component(THDi )

can<5%(plus harmonic filter)

Max.input current [A]

250

315

400

500

550

630

The output characteristic of the rectifier

Maintain the voltage (20°C)

Battery type1 and 2 :V =435Vdc (2.266 x el.)

Battery type1 and 2 :   

 V =544Vdc (2.266 x el.)

Battery type 3 :V =424Vdc (2.21 x el.)

Battery type 3 :       

V =530Vdc (2.21 x el.)

Battery type 0:the voltage value between type 1 and 2, 

Voltage regulating range: V =400~460Vdc

Battery type 0:the voltage value between type 1 and 2, Voltage regulating range: V =500~575Vdc

Charging voltage (20°C)

Battery type1 and 2 :V (%recharging<95%)=445Vdc (2.32 x el.)

Battery type1 and 2 : V (%recharging<95%)

=557Vdc (2.32 x el.)

Battery type 3 :V (%recharging<95%)=460Vdc (2.4 x el.)

Battery type 3 :V (%recharging<95%)

=576Vdc (2.4 x el.)

Battery type 0:the voltage value between type 1 and 2, 

Voltage regulating range: V =400~460Vdc

Battery type 0:the voltage value between type 1 and 2, Voltage regulating range: V =500~575Vdc

The highest charging voltage

445V

556V

The charger output voltage regulation accuracy

1%

DC ripple voltage component

≤1%

Battery

Unit number      rated voltage

192 units384VDC

240 units480VDC

Charging current settings

0.1 C(battery capacity)

The battery discharge end voltage

Battery type 1,2 and 3:no-load discharge current

Vmin=346 [V dc]

Battery type 1、2 and 3:no-load discharge current,Vmin=433 [V dc]

Battery type1,2 and 3:output current =Ah capacity

Vmin=316 [V dc]

Battery type 1、2 and 3:

output current =Ah capacity

Vmin=395 [V dc]

Battery type 1,2,3:output current >Ah capacity

Vmin=306 [V dc]

Battery type 1、2 and 3:

output current >Ah capacity

Vmin=383 [V dc]

Battery type 0:the factory set the default values,Vmin=320 [Vdc]  Regulating range: Vmin =300~360V[V dc]

Battery type 0:the factory set the default values,Vmin=400 [V dc] Regulating range: 

Vmin =375~450V[V dc]

Inverter output

Rated capacity [KVA]

160

200

250

300

350

400

Rated power [KW]

128

160

200

240

280

320

Rated voltage [V]

 380/400/415VAC three-phase four-wire

Rated current [A]

195

243

304

365

426

486

Phase voltage setting

200 ~ 244 V (control board)

Peak factor

31

Waveform

Sine wave

Voltage phase shift (degrees) 100% balanced load

± 1'

Voltage phase shift (degrees)

100% unbalanced load

± 2'

Phase voltage difference         100% balance load

± 1 %

Phase voltage difference         100% unbalanced load

± 3 %

Total harmonic content(THD v)                                100% linear load

<2%

Total harmonic content(THD v)                               100% non-linear load

<5%

Steady-state voltage stability

± 1 %

Transient voltage response

± 5 % within 10ms

Rated frequency

Same as input

Frequency stability

When asynchronous,± 0.5 %;synchronization,± 2 %

can be set to ± 1~5 %,by the panel operation

Overload

  600’ / 10’ / 1’ 110/125/150% rated current)

Short circuit 0.1s

Double input

Inverter efficiency           (load 100%)

98%

Bypass

Rated capacity [KVA]

160

200

250

300

350

400

Rated voltage [V]

 380/400/415VAC  three-phase four-wire

Input voltage range

±15 %can be adjusted from the control panel± 10 %± 20%

Rated frequency [Hz]

50 / 60

Frequency range

±2 %can be adjusted from the control panel± 5 %

“STAND-BY ON”Economic mode, the bypass switch to inverter)conversion time

2~5ms

Inverter/bypass transfer time

<1ms

Overload

10’/1’/18” 150/175/200% rated current 

Standard configuration

Feed flow protection, bypass independently isolated

NOTE: 120VAC power grid 10-200kva are available;

Product Specifications

It's popular product in Middleast and Africa market

1. adopted with full DSP control with high speed CPU 32bit,High reliable design , World-leading driver protection and VCE protection.
These all have ensured UPS with high stablity(MTBF>200,000h) and excellent performance;

2. the 6th generation IGBT inverter technology, UPS efficency reaching 90-95%.

3. World-leading UPS parallel technology, extremelt low cycle current,high stable and easy connection:
a) common battery bank, save battery cost for parallel.
b)10-80kva with parallel card only without weaver inductance thanks to the extremly low cycle current based advance control technology ;
c)Different capacity can be parallel and load share divided by UPS capacity ratio...

4. Advanced battery management:
a) Peridic battery self test .
b) default 0.1C charging current , best for battery lifespan
c) Recharge termperature compensation(optinal)

5. Remaining back up time display
by using powerful algorithm,an estimated remaining back up time can be calcualted and displayed on the LCD screen,which can help users to make a furher arrangement in event of AC input gone.

6. Event log up to 1000 items
Classified events ,easy to check and helpful for fast maintenance

7. Frequency convertor mode function input 50hz output 60hz or reverse....

8. Full frontal access of all components ,convenient for maintenance.

9. From bottom and to top air flow, so it can be installed against of the wall to save space
10. Upstream protection for installation engineer and system's safety

11. Adundant communication interface, RS232, RS485,dry contact... SNMP card( optional)

12. Colorful 7inch touch screen,with high resolution,friendly human-machine interface

13. Intelligent self-diagnosis system ; thanks to this function, if UPS failed,engineer can find out the problem in very short time